TD624ES High Performance Traffic Detector


The TD624ES is a high performance, 4 channel, microprocessor-based card detector complying to Eurocard standards. Features incorporated on this model make it an invaluable component in any ITS system.
The TD624ES Eurocard detector complies to TR0100A UK DoT for motorway use.
The TD624ES is used in typical motorway incident detection and automated signalling (MIDAS) applications.

 APPLICATIONS

 

· Speed monitoring in motorway application
· Determination of vehicle headway
· Calculation of vehicle occupancy
· Accurate high-speed vehicle speed measurement
 

 Features of the TD624ES

 

 

· Optimised Response Times:

Response times are optimised to facilitate the measurement of accurate speed and length measurement data.
· Optimised Sensitivity:
Sensitivity levels are adjustable for each channel.
These have been carefully chosen for traffic control
applications allowing adjacent lane rejection and
elimination of interference.
· Adjustable Presence Time:
A range of four presence times is available and adjustable for each channel. This facilitates operation in passage mode, limited presence or for
queue detection.
· Loop Fault Monitor:
The TD624ES provides local and remote fault output indications on an individual channel basis as required
· Sequential Polling: Scanning techniques are employed to positively eliminate crosstalk between loops connected to the same detector module.

 Using the TD624ES for incident detection in IR100



TD624ES

- Technical Data High Performance Traffic Detector
   
Self-tuning Range: 20– 1000 µH
Sensitivity: Four step adjustable on faceplate
High 0.02%L/L Med-High 0.05% L/L
Med-Low 0.1% L/L Low 0.5% L/L
Frequency:

Four step selectable on PCB
10 khz - 140 khz (Frequency dependent on loop
per channel)

Output Configuration: One presence output per channel
Presence Time: Four step adjustable on faceplate
3.5 seconds
4 minutes
35 minutes
Limited by %L/L
Response Times: Turn on 52mS ± 2.4 mS
Run off 52mS ± 2.4mS
Recovery ± 80 mS
Fault Outputs: Common open collector operates under the following conditions: Loop short/open circuit.
Indications: The following indications are provided:
2 LED per channel
1 Red - Detect
1 Red - Fault
Protection: Loop isolation transformers, zener diode clamping on loop inputs and gas discharge tube protection.
Power Requirements: 24V DC (+20%) Requirement 1.8 VA (max) @ 24V DC
Output: 50mA @ 30V DC - OPTO
Single change-over contact per output
Operating Temp Range: -40°C to +80°C ( Circuit conformally coated )
Mechanical Details :  
Standard Eurocard Dimensions: 160mm (deep) x 100mm (high)
Faceplate: 25mm wide
Connector:

2 x 32 pin card edge (DIN 41612 type B)

Hide this Panel

Your Full Name:
*
Your Contact Number:
*
Your Email Address:
*
Country:
Item interested in:
How many are you interested in?:
*
Any other information that you think we should know when quoting:
*
:: Vehicle Detection :
:: Boxed Version

TD 136
TD 250
TD 250L
TD 450L


:: Card Version

TD 422E
TD 424E
TD 422N
TD 424N
TD 524
TD 624ES


:: Vehicle Indentification :
:: Track 100

Track 100


:: Track 200

Track 200


:: Track 2000

Track 2000


:: Traffic Management :
:: IR 100

IR 100