| Input
Protection: |
Over
voltage transient protection on power lines. |
| Spike
Filter: |
On
all inputs. Protects against induced voltages on long input
lines |
| Output
Relays: |
Door
strike outputs: 5 Amperes @ 230 Volt AC, voltage free, change over
contacts. |
| Communications
Ports: |
RS-232/RS-485:
· 9600/19200 BAUD (selectable),
· 8 Data Bits,
· 1 Stop Bit,
· No Parity
· No Handshake Lines |
| Display: |
Four
digit, 7-segment LED display,
Character Height = 10mm
1 green, 1 red 3mm LED: Used to display Void or Valid in the User
menu. |
| Outputs: |
·
Door Strike Relays: Energise for a selectable duration when
a valid code is read
· Alarm Relays: Energise for selectable duration when
an alarm condition occurs.
· Buzzer output: Open-collector output for an external
buzzer; 200mA, 30V maximum.
· Reader Control outputs: Open-collector outputs,
pulled low when an invalid card is read, may be
connected
to the Reader buzzer input.
· Reader Power: 8V (+- 20%), 500mA max. |
| Inputs: |
·
Reader: Surge, over-voltage protected Wiegand/Clock
& Data inputs.
· Alarm: Surge, over-voltage protected emergency
exit input.
· Door: Surge, over-voltage protected 'door open'
inputs.
· Exit: Surge, over-voltage protected 'Free
exit' inputs. |
| Controls: |
Three
pushbuttons
· Scroll left/down
· Right/up
· Enter. |
| Memory: |
Non
Volatile retains user and system information permanently
via CR2032 3V battery (to be replaced annually) |
| Off-line
Transaction memory: |
4000
Transactions |
| User
Capacity: |
4000
Users |
| Master
Access: |
Programmable
Master Access Code |
| Power
Requirements: |
12
24 volt AC/DC
Requirement : 1 VA Maximum |
| Reaction
Time: |
0.6
seconds or better |
| Storage
Temperature: |
-
40°C to + 85°C |
| Operating
Temperature: |
-
10°C to + 60°C |
| Humidity: |
Up
to 95% relative humidity without condensation |
| Circuit
protection: |
Conformal
coating over the PCB and all components |
Housing: |
Black
powder-coated mild steel: 185mm x 124mm x 30mm |
| Connections: |
4
x M4 type bolts to be used |