| Input
Protection: |
Over-voltage
transient protection on power lines. |
| Spike
Filter: |
On
all inputs. Protects against induced voltages on long input lines |
| Output
Relays: |
Door
strike output: 1 Ampere @ 230Volt AC, voltage free, change-over
contacts. |
| Communications
Ports: |
RS-232:
· 9600/19200 BAUD (selectable),
· 8 Data Bits,
· 1 Stop Bit,
· No Parity
· No Handshake Lines |
| Display: |
Eight
character by two line liquid crystal display |
| Outputs: |
Door Strike Relay: Energised for a selectable duration when a valid
code is read. |
| Reader
Control output: |
Open-collector
output, pulled low when a card is read, may be connected to the
Reader buzzer input. |
| Reader
Power: |
6V
(+- 10%), 100mA power supply to reader.
|
| Inputs: |
Reader:
Surge, over-voltage protected Wiegand/Clock & Data inputs.
Aux input:
· Free Exit Activate: Low (>0.5 Seconds Current
Sink to 0VDC)
· Arming Activate: High (Open No connection)
|
| Controls: |
Four
pushbuttons: Mode, Enter, Up, Down |
| Memory: |
Non
Volatile - retains user and system information. Portable data backup
module also used to store and transfer memory contents. |
| User
Capacity: |
10000
Sequential Users |
Power
Requirements:
Requirement: |
1224V
AC/DC
1.5 VA Maximum |
| Reaction
Time: |
0.6
seconds or better |
| Storage
Temperature: |
-40°C
to + 85°C |
| Operating
Temperature: |
-15°C
to + 60°C |
| Humidity: |
Up
to 95% relative humidity without condensation |
| Circuit
protection: |
Conformal
coating over the PCB and all components |
| Housing: |
Black
powder-coated mild steel
83mm(W) x 109mm(H) x 33mm(D) |
| Mounting
Position: |
4xM4
type bolts to be used
96mm(H) x 60mm(W) |
| Connections: |
Screw
type, 3.5mm pitch |