| Self
Tuning Range: |
15-1500
µH |
| Sensitivity: |
Four
steps adjustable on faceplate |
|
Max-0.02% L/L |
|
Norm-0.1% L/L |
|
Min
0.5% L/L |
|
Min
+ Filter 0.5% L/L |
|
(Includes
2 second turn-on delay) |
| Frequency:
|
Four step selectable on faceplate 20-150kHz (Frequency determined
by loop geometry) |
| Output
Configuration: |
1 output relay per channel. Configuration selectable |
| Pulse
Output Duration: |
Approx
150ms |
| Presence
Time: |
1
Hour for 3% L/L Permanent
presence option |
| Operating
Modes: |
1.
Automatic Sensitivity Boost Off/On |
|
2.
Pulse/presence per channel |
|
(Pulse
on Entry only) |
| Fault
Outputs: |
Common fault monitor output relay operates under the following
conditions:
1 = Loop short/open circuit 2 = Detector/power fault |
| Indications:
|
The
following faceplate indications are provided:
1 Red on (run) indicator 1 Green LED per channel |
| Protection: |
Loop isolation transformers, zener diode clamping on loop inputs
and gas discharge tube protection. |
| Power
Requirements: |
230V
AC (+/-15%) 48-60Hz Requirement 3VA @ 230V |
| Output
Relay: |
(Rating
and Type): Presence Relay 1A @ 230V AC N/O Relay contacts
per channel Fault Relay 1A @ 230V AC Common N/O relay contacts
fail safe |
| Operating
Temperature Range: |
-40C
+70C(Circuit sealed against condensation) |
| Mechanical
Details: |
Material
ABS blend |
| Dimensions: |
113mm (high) x 56mm (wide) x 127mm (deep) |
| Mounting: |
Shelf |
| Connectors: |
Dual rear mount 11-pin submagnal, single VDE connector |
| Accessories: |
All flying leads supplied |